Compliance & Safety
Restaurant Equipment Maintenance Checklist
A preventive maintenance schedule for a commercial kitchen, sorted by how often each task comes due: daily line care, weekly boil-outs and filters, monthly coil and extinguisher checks, and the contractor visits for fire suppression and exhaust that inspectors ask to see.
The Copper Skillet
Equipment Maintenance Checklist — October 2026
Completed by: ______________________ Reviewed by: ______________________
Pre-filled with a typical full-service kitchen schedule, grouped by how often each task comes up. Tick items as they are done, edit any line to match your equipment, and print a fresh copy for each period.
Progress
0%
0 of 29 items done
Daily
Line cooks and closers, every shift
- Record walk-in, reach-in and freezer temperatures (41°F or below cold, 0°F or below frozen)
- Wipe down and degrease flat-top, char-grill grates and range tops after service
- Filter or skim fryer oil; check oil color and smell
- Empty and clean hood grease cups and wipe filters with visible buildup
- Check dish machine wash and final-rinse temperatures, or sanitizer concentration, and log them
- Clean and sanitize slicer, mixer attachments and food processor after use
- Check refrigeration door gaskets for tears and doors for a full seal
Weekly
Kitchen manager or lead cook
- Boil out fryers and replace oil on the schedule your volume needs
- Run hood filters through the dish machine or soak them in degreaser
- Delime the dish machine and clean wash arms, screens and curtains
- Clean oven interiors and combi-oven cavities; run the combi's cleaning cycle
- Check calibration of probe thermometers in an ice-water bath
- Inspect gas hoses, quick-disconnects and restraining cables on cooking equipment
Monthly
Kitchen manager
- Visually inspect every portable fire extinguisher: in place, charged, pin and seal intact (OSHA 1910.157)
- Clean condenser coils on reach-ins and under-counter units
- Clean and sanitize the ice machine bin; follow the maker's descaling schedule
- Check walk-in evaporator for ice buildup and clear the drain line
- Inspect grease trap or interceptor level and log pump-outs
- Check water filters on coffee, ice and steam equipment; replace on the maker's schedule
Quarterly
Manager with outside vendors as needed
- Have the exhaust system inspected for grease buildup at the interval NFPA 96 sets for your cooking volume
- Service walk-in refrigeration: refrigerant check, fan motors, door heaters
- Inspect gas and electrical connections behind the cooking line
- Calibrate oven and fryer thermostats against a reference thermometer
- Review the repair log and replace parts that keep failing
Every Six Months and Yearly
Licensed contractors; keep every report on file
- Kitchen fire suppression system inspection by a licensed contractor (every six months)
- Annual maintenance check on every portable fire extinguisher (OSHA 1910.157)
- Backflow preventer test, if your water utility requires one
- HVAC and make-up air unit service: belts, filters, burners
- Deep-clean behind and under all cooking equipment with the line pulled out
Why Preventive Maintenance Pays
Commercial kitchen equipment rarely fails without warning. A walk-in that is slowly icing up, a fryer thermostat that drifts, a hood filter loaded with grease — each gives weeks of signals before it becomes a lost Saturday, a spoiled delivery or a fire. A written schedule turns those signals into routine tasks with a name next to them. It also produces the paper trail that fire marshals, health inspectors and insurers ask for after something goes wrong.
The Tasks That Are Required, Not Optional
- Fire extinguishers: OSHA's rule for portable extinguishers (29 CFR 1910.157) requires a visual inspection every month and a maintenance check every year. Initial and date the tag each time.
- Exhaust system: NFPA 96 sets the minimum inspection interval for grease buildup by cooking type — monthly for solid-fuel cooking, quarterly for high-volume kitchens such as 24-hour, charbroil or wok operations, twice a year for moderate volume, and yearly for low-volume kitchens like seasonal businesses. Your fire marshal can require more.
- Hood fire suppression: inspected every six months by a licensed contractor in most jurisdictions. Keep the tag current and the report on file. Our suppression guide covers system types and what inspections cost.
- Cold holding: the FDA Food Code holds cold food at 41°F or below. Log it daily on a temperature log.
How to Use This Checklist
- Edit the lines to match your actual equipment; delete what you do not own.
- Assign each section an owner: closers for daily, the kitchen manager for weekly and monthly.
- Print a fresh copy each month and keep the signed sheets with contractor reports.
- Write repairs in the margin; the same part failing twice is a budget line, not bad luck.